The Monitored PDU enables precise measurement of power and environmental conditions, ensuring stable and transparent energy usage. With features such as inlet-level monitoring, sensor integration, and an upgradeable architecture, it supports long-term infrastructure needs. A recognised monitored PDU provider in the UAE can deliver pre-configured models for enterprise, telecom, and industrial requirements.
Product Features
- Inlet-level metering: Measures voltage, current, power, energy, and frequency.
- Environmental integration: Supports temperature and humidity sensors for rack supervision.
- SUM architecture: Sustainable, Upgradeable, Maintainable design for longer lifecycle.
- Hot-swappable modules: IP-monitored/metered models can be upgraded without downtime.
- Remote access: SNMP (V1/V2c/V3), HTTP/HTTPS, Telnet, and Modbus-RTU support.
- Flexible configuration: International plug and socket compatibility.
- Alerting: Customisable alarms for temperature, humidity, voltage, and current.
- Daisy-chain capability: One master with up to four slave units monitored centrally.
- High accuracy: ±1% metering precision with durable housing.
- Value-focused: Enhanced monitoring at a low cost for small and medium installations.
Specifications
| Category | Specification |
| Input | Nominal Voltage: 230 V; Frequency: 50/60 Hz; Phase: Single phase; Plug: IEC60309 (32A 250 VAC 2P+E) / Legrand; Power Cord: 3 × 6.0 mm² × 3 m; Max Input Current: 32 A; Rated Input Current: 32 A; Wiring: L-N |
| Power Capacity | Output Power: 7360 W; Nominal Output Voltage: 230 V; Max Output Current: 32 A |
| Output | 24 × IEC 320 C13; 8 × IEC 320 C19 |
| Protection | 2 × 1P 16A master air circuit breakers, overload protection |
| Monitoring | Input/Phase/Circuit metering, breaker status monitoring, ±1% accuracy |
| Environmental Monitoring | Temperature, Humidity |
| Monitoring Parameters | Voltage, Current, Active Power, Apparent Power, Energy, Power Factor, Frequency |
| Communication Access | SNMP (V1/V2c/V3), HTTP/HTTPS, Telnet, Modbus-RTU |
| Alerts | Voltage, Current; optional: Temperature, Humidity |
| Services | TFTP, SMTP |
| Daisy-Chain Capability | 1 Master + 4 Slaves |
| Compliance | EMC: EN 55022, EN 61000; Safety: IEC/EN 60950, IEC/EN 62368; Environmental: RoHS 2.0 |
| Physical Specs | Dimensions: 482.6 × 220 × 44.4 mm; Weight: 3.5 kg; Box: 525 × 405 × 105 mm, 4 kg; Mounting: 1U, brackets both ends; Distance: 465 mm |
| Environmental Range | Operating Temperature: 0-45 °C; Humidity: 5-95%; Elevation: 0-3000 m |
Applications
DConnect monitored PDUs are ideal for:
- Data Centres: Ensuring business-critical energy monitoring and compliance.
- Telecom Rooms: Providing accurate rack-level supervision.
- Colocation Facilities: Supporting tenant visibility of energy consumption.
- Industrial Automation: Facilitating precise measurement of controllers and machinery loads.
- Enterprise IT: Delivering power and environment monitoring in server and network racks.
Available Configurations
- Vertical or horizontal mounting.
- Outlet mix: IEC C13 and C19.
- Input plug options: IEC60309, IEC320, BS1363, and others.
- Daisy-chain for multi-unit monitoring.
- Environmental sensor kits available.
- Custom configurations to match enterprise and telecom standards.
Specifications and bundles may vary by model. Request a quotation for exact details.