Row Mount DX Package Type

Product Description

Attom’s Row Mount DX Package Type cooling unit is made to sit right inside the rack row where the heat actually builds, not at the edge of the room where airflow gets messy. The entire unit is packaged, so it doesn’t rely on external chillers or long pipes to get started. It goes where the racks are and cools without needing to rework the room around it.

It runs with an inverter compressor and EC fans, which just means it reacts to the load instead of blasting air all the time. The expansion valve is electronic, so refrigerant flow stays efficient without needing constant tuning. The cabinet doors are sealed, service access is simple, and it’s quiet enough that you can stand near it without getting drowned out.

If you’re working on data center cooling systems in the UAE or planning to buy Row Mount DX Package Type setups that fit real-world spaces, this option gets it done without adding complexity.

Product Features

Here are the capabilities that come with the Row Mount DX Package Type:

  • Inline Rack Cooling: The unit installs directly in the row beside racks without needing external cooling equipment.
    Inverter Compressor: The system adjusts cooling output in real time based on heat load without cycling constantly.
    EC Fan System: The fans scale airflow depending on rack demand instead of staying fixed at full speed.
    Electronic Valve Control: An electronic expansion valve keeps refrigerant flow steady and efficient across temperature shifts.
    Control Integration: A precision controller manages internal functions and connects to building monitoring systems.
    Refrigerant Type: It uses R410A, which hits performance targets and meets environmental standards.
    Service Layout: The cabinet includes a slide-out electric box and filters that can be replaced without tools.
    Add-on Options: It supports SNMP cards, leak sensors, a condensate pump, and dual power input kits depending on site needs.
    Flexible Plumbing: You can run copper piping from either the top or the bottom depending on the rack layout.
    Low Noise Build: Compressor placement is done in a way that reduces the sound level during operation.

Specifications

 

Component Details
Mount Type Row-mounted DX packaged unit
Cooling Hardware Inverter compressor, EC fans, electronic expansion valve
Refrigerant R410A green refrigerant
Control Interface Precision controller with BMS integration and touchscreen
Maintenance Access Slide-drawer electric box, G4 filters, sealed doors
Add-On Options SNMP monitoring card, condensate pump, leak detection, dual power input
Piping Configuration Supports top or bottom copper piping setup
Noise Design Internal layout optimized to reduce compressor sound
Unit Capacity Options Available in multiple performance variants based on cooling need