Features of LAU500
- Remote connection is possible via Ethernet or LAN
- Network can be monitored via Unipass
- Encrypted communication with readers
- Latest protocols in communications in OSDP and SSCP is supported
- Quick and easy installation
- Unipass can be used for network monitoring
Specifications of LAU500
| Dimensions | · Metal housing: 150 x 300 x 80 mm
· DIN housing: 163 x 120 x 60 mm |
| Weight | 200g |
| Available Options | I/O-module, Tamper switch (anti-sabotage), OSDP/Wiegand converter (dual), SAM module (enables transparent mode) |
| Input Voltage | 12 V DC (powered by the MC) or external power supply |
| Input Range | 10-15 V |
| Minimum amperage | 2 A (Depending on peripherals) |
| Number of readers | Max 2 readers (entry/exit on 1 door or 2 entry-only doors) |
| Communication Protocols | RS-485 (OSDP and SSCP) to readers
RS-485 with encryption capability between LAU500 and MC504/510/516 |
| Operating Temperature | 0 to 60 Degrees Celsius |