Product Benefits
- Autonomous lift access control
- Automatic transfer of events to the server
- Enhanced memory capacity: up to 200.000 ID media (key fobs & cards) and 30.000 events
- Scheduled automatic floor opening and closing
- Fire control function to allow emergency evacuation
- Integrated Ethernet network module and possibility to enable AES Encryption (Unipass 6.6.3+) or encryption using TLS certificates (Unipass 8+)
- Remote connection to the controller possible via the network (firmware upgrades, configurating OSDP/SSCP readers)
Technical Specifications:
- Hardware:
Version: UT 4
Dimensions (L x H x D): - Housing:
12 V: 300 x 300 x 80 mm
230 V: 450 x 300 x 80 mm - Weight
Housing:
12 V: ≃2.5 kg
230 V: ≃4.2 kg (battery not included)
DIN: 369 g
Board: 199 g
Conformity: CE
Available options: Backup power supply (BPS), I/O module
Related products: RFID reader - Electrical
Input voltage: 12 V DC (+20 %/-10 %)
100 V to 240 V AC (50-60 Hz) for 230 V configurations
Typical power consumption: 800 mA at 12 V DC (excluding peripherals)
Power failure protection: ≃5 years of data retention : The intern clock keeps working for approximately one week in case of power outage and communication failure.
Communication
- Server/Network connectivity: RJ45 ethernet 10 Base-T or 100 Base-TX (auto-sensing)
- Communication security: AES (Unipass 6.6.3+) & TLS (Unipass 8+)
- Reader connectivity :1 reader (Wiegand, OSDP or SSCP)
2 LEDs and 1 beeper / reader - Reader compatibility: All IDtech readers and most third-party readers
QR-code, biometric, licence plate, and long-distance readers - Identification technologies: iClass®, Seos™, MIFARE® Classic, DESFire®EV1/EV2/EV3.
- Communication protocols: Wiegand, OSDP and SSCP
- Max. wiring distance: The reader must be installed in the lift cabin.
- Door opening time :12 inputs and 8 outputs
- In option: additional I/O module with 8 inputs and 4 outputs
- I/O: RJ45 ethernet 10 Base-T or 100 Base-TX (auto-sensing)
Environment
Mounting: Wall mount, DIN-rail
Operating temperature: 0 to 60 °C
Recommendations
Technical recommendations:
- There is no restriction on the number of lift controllers in the same access control system.
- Not compatible with lifts with a destination control system
- Floor contacts are available to the lift manufacturer.
Wiring recommendations:
- Wiring between the elevator and the IDtech lift controller, including the installation of a badge reader in the lift cabin, shall be installed by the lift installer according to IDtech specifications.
- Power supply: 12 V – 2×2.5 mm2 LIYY / VTMB; 230 V – XVB 3G1.5 mm2
- I/O module: 2×0.75 mm2 + 2x2x0.22 mm2 twisted alarm cable
- Wiegand: 2×0.75 mm2 + 6×0.22 mm2 shielded alarm cable
- OSDP: 2×0.75 mm2 + 2x2x0.22 mm2 twisted alarm cable